新闻资讯PCBanner 新闻资讯wapBanner
首页 > Flow Meters' Diary > News of Flow Meter > pentaerythrite oval flowmeter
Submit a message
  • Name*
  • Tel*
  • Email*
  • Content*
  •  

Friendship tips

    Shanghai JSN Micro Flow Meter CO.,LTD as a high-tech industrial products manufacturing and complete sets of product sales, R & D, production, processing and sales as one, with independent import and export rights of enterprises.
    The company's main flow meter, level meter, and pressure controller, temperature controller, analytical instruments and other various types of instrumentation. To solve all kinds of problems, and provide complete sales service for customers with professional technical point of view.
International service telephone
(86)021-57632436

pentaerythrite oval flowmeter

Date:2018-01-03 source:

  pentaerythrite oval flowmeter   email: porter@microflowmeter.com

ShanghaiJSN Micro Flow Meter CO.,LTD main products: super micro liquid flow meter,oval gear flow meter,mass flow meter.spur gear flow meter,gear pump,gear metering pump etc dozensof categories of instrument products.Since it’s established, “Pursuit of excellence, creation of quality products,honesty and credit, and dedication of first-class” are our unchanging pursuits,and the ultimate goal of customer satisfaction is our marketing services. Inorder to continuously improve our products and services, we are makingunremitting efforts! The purpose of the company is to provide and recommend avariety of effective and reliable measurement methods based on our many yearsof work experience. We sincerely welcome all groups or individuals from allwalks of life to join our company in order to achieve common development andimprovement, make the due contribution to the motherland automationindustry.

 pentaerythrite oval flowmeter

pentaerythrite oval flowmeter

Withthe development of society, the state pays more and more attention to theprocess automation instrumentation industry. However, the Oval gear flow meter industryhas been in a vacancy and has been monopolized by major foreign brands such asMax, KRACHT, OVAL, etc. , People have long endured the expensive, longdelivery, the sale can not be resolved in time and so on, such as semiconductorchip cutting a set of equipment on the millions, once the instrument problems,loss unimaginable, the slayer saw these phenomena, Resolutely resigned assenior engineer in the position of Siemens, the establishment of ShanghaiJi-sheng Instruments Co., Ltd., with great concentration on research anddevelopment of gear flow meter. We have Oval gear flow meter has been awarded anumber of certificates, it is no exaggeration to say that Qishen production Ovalgear flow meter For example, many customers replace the OVAL LSF40 with ourCX-M5-AL because it costs less than half of the LSF40, but has twice the rangethan it does and has the same accuracy.

TheCX-M and G-series mirco flow meters are the world"s new volumetric flowmetersintroduced by BASF in 2011. Since its establishment, the CX-M oval gear flowmeter and the G-series mirco flow meters have been selling well in the marketfor more than 100,000 units a year since they were sold. The third generationlaunched in 2017, with more than 90% accuracy and stability, won thecertification of the National Bureau of Metrology. The quality and reliabilityof Shanghai JiShen instruments need not worry. According to the statistics ofChina Instrument Association, Deep flow meter reliability has always beenranked in the top 3, especially in the long-term statistics failure rate is farbelow the industry average, deep advocate "the best after-sales service isno service", but also achieved a continuous three years without qualitycomplaints .

oval flowmeter

pentaerythrite oval flowmeter

The CX-M and G series gearflow meters consist of a flow transmitter and a display. The oval gear flowmeter metering chamber of the flow transmitter has a pair of elliptical orcircular measuring gears. The gears and the measuring chamber form severalknown volumes. The cavity acts as a metering unit. Under the influence of thedifferential pressure between the inlet and outlet, the gear is driven torotate, and the imported liquid is continuously metered into the outlet aftermeasuring the metering chamber. At the same time, the sensor generates acorresponding electrical signal and sends it to the display section. Afterpartial treatment, the instantaneous flow and cumulative flow of the liquid canbe displayed.

 pentaerythrite oval flowmeter

pentaerythrite oval flowmeter

Technicaldata of Gear type flow meter

Model

K-factor

Minimum  flow

Flow  range

Accuracy

G0.025

0.025ml

0.001L/Min

0.008~2L/Min

0.5%

G0.04

0.04ml

0.004L/Min

0.2~4  L/min

0.5%

G0.1

0.4ml

0.008L/Min

0.01~8L/min

0.5%

G0.2

0.245ml

0.01L/Min

0.16~16  L/min

0.5%

G0.4

0.4ml

0.01L/Min

0.16~16  L/min

0.5%

G1

1.036ml

0.02L/Min

0.4~80  L/min

0.5%


What are the precautions for the gear flow meter?

1) When the flow exceeds the specified maximum flow rate, the Oval gear flow meter wear increases with the increase of the rotation speed, and the pressure loss increases sharply, should be avoided. Less than the minimum flow, although still able to measure, but the error increases. Flow meter The starting flow is about 2% of the maximum flow, and the normal working flow is preferably 70%-80% of the maximum flow.

2) Deep-rooted flowmeter is used with various viscosity media from 0.3 ~ 100000cps, different viscosity media will affect the range, the following single must be noted

3) The measured liquid temperature should not exceed the specified value, otherwise, the instrument can not work properly, or even stuck, the counter part is easily damaged at high temperatures. Liquid temperature changes will also cause additional errors in viscosity.